HELION · Restart of the palletizing cell

Themenportal · ausschließlich ansehen. Keine Anmeldung, Bearbeitung, Speicherung oder KI-Nutzung.

ISO 9001: 6.1 / 8.3. Four UCA types, control structure, causal scenarios and verifiable design requirements. Fictitious industrial learning example. All figures, roles and evidence are simulated; no real release, customer validation or effectiveness confirmation.

STPA AI Tool

Public example · read-only

42 %

STPA-
Analysis sheet

System: HELION · Robotic palletizing cell
Analysis objective: Identify unsafe control actions during restart
System boundary: Robot, cell control, safety door, operation; evaluate safety integrity separately according to relevant rules.
Analyst / Team: Safety team (fictitious roles)
Date / revision: 2026-10-01
Scope: 2 L · 1 H · 4 UCA · 4 Scenarios

Analysis purpose

Losses
L1Injury to a person in the robot area
L2Damage to equipment and product
Hazards
H1Robot moves while a person is in the danger zone.L1 / L2
Safety Constraints
SC1Movement only after secured release state; no automatic restart after door closure.H1

Control structure

Controller / Control units:
C1 Cell controlC2 Operator
Control actions ↓
Cell controlRobotEnable movement
OperatorCell controlAcknowledge
Cell controlRobotStop
Feedback / Feedback ↑
Door monitoringCell controlDoor status and diagnosis

Unsafe Control Actions

Nr.Control actionUCA typeDescription (context, why dangerous)HazardController constraint (safety requirement)
Root Cause AnalysisStop1 · Not providedStop is not issued when the door is open.H1
UCA2Enable movement2 · Incorrectly providedMotion enable is issued while a person is in the hazardous area.H1
UCA3Enable movement3 · Incorrect timingEnable is issued too early before the restart check is completed.H1
UCA4Enable movement4 · Too long / too shortMotion enable remains active for too long after the door is opened.H1

Causal scenarios & actions

Nr.UCAScenario typeCause / ScenarioInterfaceExisting controlActionRequirement
S1Root Cause AnalysisA · UCA root causeOutdated process model: Door signal is not plausibility checked.Door monitoring ↔ cell control ↔ robotConservative safe state in case of diagnostic error; intentional restart.Validation: Inject door change, signal loss and sequence error; 100 repetitions per case. Responsible: Automation, 30.10.2026; independent safety review.SC1: No restart without confirmed safe conditions; check measurement times against approved safety requirements.
S2UCA2A · UCA root causeDoor closed is confused with hazardous area clear.Door monitoring ↔ cell control ↔ robotConservative safe state in case of diagnostic error; intentional restart.Validation: Inject door change, signal loss and sequence error; 100 repetitions per case. Responsible: Automation, 30.10.2026; independent safety review.SC1: No restart without confirmed safe conditions; check measurement times against approved safety requirements.
S3UCA3A · UCA root causeAcknowledgment and door signal are evaluated in the wrong order.Door monitoring ↔ cell control ↔ robotConservative safe state in case of diagnostic error; intentional restart.Validation: Inject door change, signal loss and sequence error; 100 repetitions per case. Responsible: Automation, 30.10.2026; independent safety review.SC1: No restart without confirmed safe conditions; check measurement times against approved safety requirements.
S4UCA4A · UCA root causeSignal loss is interpreted as unchanged release status.Door monitoring ↔ cell control ↔ robotConservative safe state in case of diagnostic error; intentional restart.Validation: Inject door change, signal loss and sequence error; 100 repetitions per case. Responsible: Automation, 30.10.2026; independent safety review.SC1: No restart without confirmed safe conditions; check measurement times against approved safety requirements.

Completion

Result: 4 Actions · 4 Requirements derived
Analyst / Signature: Safety team (fictitious roles)
Date / revision: 2026-10-01
STPA – System-Theoretic Process Analysis (according to Leveson/Thomas) · Analysis objective → Control structure → UCAs → Causal scenarios → Actions28.11.2026